| CPU 1507S V 2.x(1個浮點授權), 僅能在SIMATIC IPC上使用 |
| Enclosed soft starter, Controller 3RW40471BB14, Std duty rating 30Hp @200V, Std duty current rating 98A, Control voltage 110-230 AC/DC, Combination type, 17*** circuit breaker, Enclosure type 3/3R, Weather proof outdoor use CPT Std Capacity 480/240:120V CPT Std Capacity 480/240:120V | ||
| product brand name | Class 74 | |
| design of the product | Enclosed soft starter with motor circuit protector | |
| special product feature | Control transformer, built-in overload relay and bypass contactor included. | |
| General technical data | ||
| weight [lb] | 87 lb | |
| Height x Width x Depth [in] | 46 × 20 × 10 in | |
| touch protection against electrical shock | NA for enclosed products | |
| installation altitude [ft] at height above sea level maximum | 6560 ft | |
| ambient temperature [°F] | ||
| ● during storage | -22 ... +149 °F | |
| ● during operation | -4 ... +104 °F | |
| ambient temperature | ||
| ● during storage | -30 ... +65 °C | |
| ● during operation | -20 ... +40 °C | |
| country of origin | USA | |
| Power and control electronics | ||
| manufacturer's article number of soft starter | 3RW40471BB14 | |
| number of poles for main current circuit | 3 | |
| design of power semiconductors (thyristors) for soft starter control | 2 controlled phases | |
| operating range factor supply voltage rated value | 0.85 ... 1.1 | |
| operating range factor of control voltage rated value | 0.85 ... 1.1 | |
| operating condition for standard duty | Class 10 standard duty (350% of motor FLA for 10 seconds) | |
| operating condition for severe duty | NA | |
| Features and functions | ||
| ramp-up (soft starting)/ramp-down (soft stop) | Yes | |
| starting voltage [%] | 40 ... 100 % | |
| stopping voltage [%] | 40 ... 100 % | |
| voltage ramp | Yes | |
| ramp-up time | 0 ... 20 s | |
| ramp-down time | 0 ... 20 s | |
| torque control | No | |
| adjustable current limitation | Yes | |
| creep speed in both directions of rotation | No | |
| pump ramp down | No | |
| integrated bypass contact system | Yes | |
| external isolation contactor | Yes | |
| intrinsic device protection | Yes | |
| overload protection | Yes | |
| trip class | Class 5 / 15 / 20 | |
| reset function | Manual, automatic and remote | |
| remote reset function | No | |
| thermistor motor protection | No | |
| inside-delta circuit | No | |
| breakaway pulse | No | |
| DC braking | No | |
| combined braking | No | |
| motor heating | No | |
| configuration of control input 1 | ON / OFF | |
| configuration of control input 2 | NA | |
| configuration of control input 3 | NA | |
| configuration of control input 4 | NA | |
| configuration of relay output 1 | ON / RUN | |
| configuration of relay output 2 | BYPASSED | |
| configuration of relay output 3 | OVERLOAD / FAILURE | |
| configuration of relay output 4 | NA | |
| display version | 4 LEDs | |
| operating measured value display | No | |
| product extension optional human machine interface module | No | |
| type of communication optional | None | |
| error logbook | No | |
| event list | No | |
| slave pointer function | No | |
| trace function | No | |
| number of parameter sets | 1 | |
| engineering software (Soft Starter ES) | No | |
| disconnector functionality | Yes | |
| Contactor | ||
| size of contactor | NA | |
| Coil | ||
| type of voltage of the control supply voltage | AC/DC | |
| control supply voltage | ||
| ● at DC rated value | 110 ... 230 V | |
| ● at AC at 50 Hz rated value | 110 ... 230 V | |
| ● at AC at 60 Hz rated value | 110 ... 230 V | |
| Enclosure | ||
| degree of protection NEMA rating | 3, 3R | |
| degree of protection NEMA rating of the enclosure | NEMA 3/3R | |
| design of the housing | Weather proof for outdoor use | |
| type of cooling | None | |
| Circuit Breaker | ||
| type of the motor protection | Motor circuit protector (magnetic trip only) | |
| operational current of motor circuit breaker rated value | 175 A | |
| adjustable current response value current of instantaneous short-circuit trip unit | 900 ... 2000 A | |
| Mounting/wiring | ||
| mounting position | Vertical | |
| fastening method | Surface mounting and installation | |
| wire length between motor starter and motor maximum | 300 m | |
| type of electrical connection for supply voltage line-side | Box lug | |
| type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded | 1x (6 AWG ... 350 Kcmil) or 1x (4 AWG ... 350 Kcmil) | |
| temperature of the conductor for supply maximum permissible | 75 °C | |
| material of the conductor for supply | AL or CU | |
| type of electrical connection for load-side outgoing feeder | Box lug | |
| tightening torque [lbf·in] for load-side outgoing feeder | 58 ... 58 lbf·in | |
| type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multi-stranded | 3x (10 ... 1/0 AWG) (front only) or 2x (10 ... 1/0 AWG) (back only) or 1x (10 ... 2/0 AWG) (both front & back) | |
| temperature of the conductor for load-side outgoing feeder maximum permissible | 75 °C | |
| material of the conductor for load-side outgoing feeder | CU | |
| type of electrical connection for auxiliary and control circuit | Screw-type terminals | |
| tightening torque [lbf·in] for auxiliary and control contacts with screw-type terminals | 7 ... 10 lbf·in | |
| type of connectable conductor cross-sections at AWG cables for auxiliary and control contacts | 2x (20 ... 14 AWG) | |
| temperature of the conductor for auxiliary and control contacts maximum permissible | 75 °C | |
| material of the conductor for auxiliary and control contacts | CU | |
| Short-circuit current rating | ||
| design of the short-circuit trip | Motor circuit protector (magnetic trip only) | |
| breaking capacity maximum short-circuit current (Icu) | ||
| ● at 240 V | 42 kA | |
| ● at 480 V | 42 kA | |
| ● at 600 V | 0 kA | |
| certificate of suitability | NEMA ICS 2; UL 508A | |
| Further information | ||
|
Industrial Controls - Product Overview (Catalogs, Brochures,…)
|
||
|
Industry Mall (Online ordering system)
|
||
|
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
|
||
|
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
|
||
|
Certificates/approvals
|
||
品類齊全
省心省力,一站購齊
一對一客服
選型詢價,快速響應
貨期保障
多倉直發,貨期無憂
正品貨源
正品保障,誠信服務